Boiler type KP SLIM 15kW with pellet feeder - type 5th class EcoDesign

KP SLIM boilers burn wood pellets. We have equipped it with a self-cleaning pellet burner with an igniter and a flame sensor.

  • Energy efficiency class: A+
  • 18,300.00 zł
  • szt.
  • Payment in cash, Payment via bank transfer, eRaty Santander Consumer Bank, Bezpieczny, szybki przelew - Przelewy24, Płatności Ratalne i odroczone
  • Check installments
  • Check installments

The product is shipped within 24 hours.

Nominal boiler power [kW]: 15
Basic fuel: Pellet
Area of ​​the heated room [m2]: 100-150
Water capacity: 144
Fuel consumption - max [kg/h]: 3,4
Chimney draft [mbar]: 0,1
Boiler weight with burner [kg]: 300
Thermal efficiency [%]: 93,2
Working pressure [bar]: 1,2 *
Water test pressure [bar]: 4
Fuel mass in the container [kg]: 160
Charging chamber capacity [liter]: 128
Charging opening [mm]: 677x428
max. operating temperature [C*]: 90
Min. return temperature [C*]: 50
Min. boiler water temperature [C*]: 10
Total width [mm]: 717
Depth [mm]: 1205
Height [mm]: 1512
Flue outlet diameter [mm]: 155
Connections [mm]: DN 25
Power supply [A/W]: 0,26/60
Electric power consumption at 100% power [W/kWh]: 60
Electric power consumption at 30% power [W/kWh]: 30
Standby power consumption [W]: 4
  Description

 

 

KP SLIM+ is a modern compact boiler that will ideally find its place in tight boiler rooms. It meets the requirements of class 5 and ecodesign. The flame tube exchanger makes this device characterized by high efficiency and high heat absorption from exhaust gases. Equipped with a modern drop-in burner with an igniter, an optical sensor and an internal feeder. The innovative design of the burner enables clean and economical combustion.

The power of 15kW meets the requirements of a higher standard and you can apply for a high subsidy.

 

The boiler has a class 5 certificate in accordance with the PN-EN 303-5: 2012 standard and meets the conditions of Ecodesign called Ecoproject

Boiler efficiency above 90%

Possibility of installation in a closed system after the heat dissipation system

Heiztechnik burner

6mm thick sheets

Warranty for the boiler 5 years, for the controller and the feeding system 2 years

Possibility to connect the Internet module

 

What fuel to use?

Basic fuel 

pellets

 

 

 

  Burner

 

Pellet burner with automatic slag scraper, automation and feeder

●A modern drop-in burner with an igniter, an optical sensor and an internal feeder.

● The burner meets the requirements of class 5 in accordance with the PN-EN 15270:2008 standard.

The innovative design of the burner enables the emission of boiler flue gases in the 5th class according to the 303-5:2012 standard.

● Extensive distribution of primary and secondary air ensures the highest combustion quality. The air curtain at the end of the burner tube ensures optimal afterburning of the exhaust gases

● A regular octagonal combustion chamber with a V-shaped floor ensures high combustion efficiency when operating with reduced load - below 25% of nominal power

● The burner is equipped with a slag scraper, which is activated periodically by the boiler automatics to prevent the accumulation of slag on the furnace

● The ergonomic design of the burner reduces the time of service - cleaning, replacement of the igniter, replacement of sensors. The slanted location of the igniter prevents it from getting dirty and prematurely worn out.

● The Brager Expert algorithm is individually programmed for each boiler, which automatically selects operating parameters and modulates the burner power depending on the boiler temperature, which reduces the amount of fuel consumed

 

 

  Boiler regulator - controller

 

 

The regulation of the boiler's thermal power is carried out by precise dosing of air and fuel supplied to the combustion process. In order to reduce temperature fluctuations and increase the stability of the combustion process, a modified proportional algorithm was used in the device
In order to obtain the required thermal comfort in heated rooms, the controller constantly controls all parameters of the boiler and heating installation, presenting them on a legible TFT display. It also offers the function of preparing hot utility water (HUW) in the SUMMER, WINTER mode, the ability to connect a room thermostat and an additional room desktop. The regulator supports the operation of one mixing valve system as standard, but this value can be increased to five mixing valve modules by connecting dedicated expansion modules . The implemented functions allow you to control the operation of three-way and four-way valves in the floor or radiator mode, with or without weather control. In addition, the controller offers control of the operation of the valve pump. An additional advantage is the ability to connect the controller to the Internet or GSM using the Media Bord 200 and Media Bord 100 modules. The device has a modern algorithm for automatic regulation of the BRAGER EXPERT combustion process. It allows for continuous operation of the boiler, reducing pollutant emissions and extending its service life.

 

 

 
  Insight

 